Hydrant System

External yard hydrant and internal wet-riser systems with auto-start electric and diesel pump sets. High-flow output (900–1800 LPM) for large-scale firefighting. Designed as per IS:3844 and NBC standards.

Flow Rate

900–1800 LPM per outlet

System Pressure

3.5–7.0 kg/cm²

Pump Configuration

Electric + Diesel + Jockey

WhatsApp
MSME Registered Free Site Visit Installation + AMC
Hydrant System

Hydrant System

IS:3844 / IS:5290 / NBC 2016

Certified

Working Principle

How It Works

A fire hydrant system stores large volumes of water in a dedicated overhead or underground tank. Motor-driven pump sets (electric + diesel backup) maintain constant pressure in a ring main pipework network. Firefighters or trained personnel connect a fire hose to landing valves on each floor and direct a high-volume water jet at the fire. The jockey pump runs continuously to compensate for minor pressure drops, alerting the system if flow demand increases suddenly.

Product Range

Available Types & Variants

External Yard Hydrant Post
Internal Wet Riser with Landing Valves
Combined Hydrant & Hose Reel
Single-Outlet Landing Valve (63mm)
Double-Outlet Landing Valve (63mm)
Inward Flow Inlet (fire brigade connection)

What You Get

Key Features

External yard and internal wet-riser systems
High flow: 900–1800 LPM per outlet
Auto-start electric + diesel + jockey pump set
Terrace tank interconnection for gravity backup
Single and double-headed landing valves per floor

Use Cases

Where It's Used

Industrial Plants
High-rise Buildings
Hospitals
Educational Campuses
Warehouses

At a Glance

Technical Specifications

Flow Rate

900–1800 LPM per outlet

System Pressure

3.5–7.0 kg/cm²

Pump Configuration

Electric + Diesel + Jockey

Landing Valve

63mm / 100mm instantaneous

Certification

IS:3844 / IS:5290 / NBC 2016

Keep It Ready

Maintenance & AMC Tips

1

Annual flow test — measure actual flow vs design specification

2

Monthly check of all pump auto-start function and pressure settings

3

Inspect valves, couplings, and landing valve outlets quarterly

4

Drain and flush the system annually to prevent corrosion deposits

5

Verify terrace tank water level is maintained and inlet valve is open

Legal & Compliance Requirement

Fire hydrant systems are mandated by NBC 2016 for industrial buildings above 500 m², high-rise buildings above 15m, hospitals, hotels, and large storage facilities. They are the primary firefighting tool used by fire brigade personnel on arrival and are a non-negotiable requirement for NOC approval for most large commercial and industrial premises in India.