
Fire SafetyEquipment
Complete range of fire protection equipment — extinguishers, alarm panels, sprinklers, hydrants, suppression systems, signage, and rescue gear — certified, supplied, installed, and maintained by our expert team. Tap any equipment to view its complete details.
ISI / BIS Certified
Every item — from extinguishers to suppression systems — meets IS standards, ready for fire NOC inspection.
Supply, Install & AMC
End-to-end service: product supply, professional installation, refilling, and annual maintenance contracts.
Pan-Haryana Service
Based in Kaithal, serving schools, hospitals, hotels, and factories across Haryana with rapid on-site support.
Trusted Since 2012
Over a decade of fire protection experience across educational, industrial, and commercial premises.
Most EssentialIS:2878 / IS:15683
Fire Extinguisher
Available in DCP, CO2, Water, and Foam variants — ISI/BIS certified for Class A, B, C, and E fires. Capacities from 1 kg portable to 50 kg trolley-mounted units. Annual refilling and maintenance support included.
View Full Details
Central ControlIS:2189 / EN 54
Fire Alarm Panel
Conventional (2–16 zone) and addressable (up to 256 devices) fire alarm control panels with 24-hour battery backup. Monitors all detectors, activates sounders, and isolates affected zones.
View Full Details
Early WarningIS:11360 / EN 54-7
Smoke Detector
Optical and ionization smoke detectors for early fire detection in corridors, offices, and server rooms. 360° smoke entry design with LED alarm indicator. Works with both conventional and addressable panels.
View Full Details
High-Temp AreasIS:11360 / EN 54-5
Heat Detector
Fixed temperature (57°C / 90°C) and rate-of-rise heat detectors for kitchens, boiler rooms, and dusty factories where smoke detectors would give false alarms. Highly reliable, no false alarms from cooking fumes.
View Full Details
Alarm SounderIS:2189 / EN 54-3 / EN 54-11
Fire Bell / Hooter & MCP
Electric fire bells (6", 8", 10"), electronic sounders, and Manual Call Points (break-glass MCP) for immediate alarm activation. IP54/IP65 rated, 85–100 dB output. Available in conventional and addressable types.
View Full Details
Auto SuppressionIS:15105 / NFPA 13 / NBC 2016
Sprinkler System
Wet pipe and dry pipe automatic sprinkler systems that activate independently at 68°C without human intervention. Only heads in the fire-affected zone discharge water. Designed per NBC 2016 and TAC guidelines.
View Full Details
Heavy-DutyIS:3844 / IS:5290 / NBC 2016
Hydrant System
External yard hydrant and internal wet-riser systems with auto-start electric and diesel pump sets. High-flow output (900–1800 LPM) for large-scale firefighting. Designed as per IS:3844 and NBC standards.
View Full Details
First AidIS:884 / IS:8423
Hose Reel
30-metre rubber fire hose reels in swing, drum, and recessed cabinet types. 19mm/25mm bore with manual or automatic shut-off valve. Easy to operate without special training for early-stage fire control.
View Full Details
Evacuation SafetyIS:3646 / IS:9583 / EN 1838
Emergency Exit Lighting
LED emergency bulkhead lights and illuminated exit signs with minimum 3-hour battery backup. Activate automatically on mains failure. Available in maintained, non-maintained, and central-battery configurations.
View Full Details
Server & Electrical RiskNFPA 2001 / IS:15493
Fire Suppression System (Clean Agent)
FM-200, Novec 1230, and CO2-based clean agent suppression systems that extinguish fires within seconds without leaving residue or damaging sensitive equipment. Ideal for areas where water-based systems would cause more harm than the fire itself.
View Full Details
Wet ChemicalUL 300 / NFPA 96 / IS:15493
Kitchen Fire Suppression System
Automatic wet-chemical suppression systems engineered for commercial kitchens — protecting cooking ranges, fryers, griddles, and exhaust ducts. Detects heat and discharges suppressant directly onto the hazard while cutting fuel and electrical supply.
View Full Details
CompartmentationIS:3614 / EN 1634 / NBC 2016
Fire-Rated Doors
30, 60, and 120-minute fire-rated steel doors with intumescent seals and panic hardware that contain fire and smoke spread between compartments — buying critical time for safe evacuation. Supplied with certified vision panels and self-closing devices.
View Full Details
WayfindingIS:12349 / ISO 7010 / NBC 2016
Fire Safety Signage & Evacuation Plans
Photoluminescent and illuminated exit signs, floor evacuation maps, equipment location markers, and mandatory hazard signage that guide occupants to safety even in smoke-filled, low-visibility conditions.
View Full Details
Mass NotificationEN 54-16 / EN 54-24 / IS:2189
Public Address & Voice Evacuation (PAVA) System
Integrated voice alarm and public address systems that deliver clear, pre-recorded or live evacuation instructions across large buildings — reducing panic and enabling phased, zone-wise evacuation during emergencies.
View Full Details
Rescue & ResponseIS:10245 / EN 137
Self-Contained Breathing Apparatus (BA Set)
Compressed-air breathing apparatus sets that protect firefighters and rescue teams from smoke, toxic gases, and oxygen-deficient atmospheres during firefighting and confined-space rescue operations.
View Full Details
First ResponseIS:12652 / BS EN 1869
Fire Blanket & Safety Kit
Fire-retardant glass-fibre blankets and first-response safety kits for smothering small fires and wrapping around a person whose clothing has caught fire — a simple, training-free tool for kitchens, labs, and homes.
View Full DetailsNeed Help Choosing the Right Equipment?
Our fire safety engineers will assess your site and recommend the right combination of equipment, installation, and AMC support — no obligation.