Auto SuppressionIS:15105 / NFPA 13 / NBC 2016

Sprinkler System

Wet pipe and dry pipe automatic sprinkler systems that activate independently at 68°C without human intervention. Only heads in the fire-affected zone discharge water. Designed per NBC 2016 and TAC guidelines.

Activation Temp.

68°C standard (57–260°C range)

Coverage Per Head

9–12 m²

Design Pressure

0.5–1.2 bar minimum at head

WhatsApp
ISI/BIS Certified Free Site Visit Installation + AMC
Sprinkler System

Sprinkler System

IS:15105 / NFPA 13 / NBC 2016

Certified

Working Principle

How It Works

Each sprinkler head contains a heat-sensitive glass bulb filled with glycerine-based liquid. At 68°C, the liquid expands and shatters the bulb, allowing pressurised water from the pipe network to flow and discharge in a controlled spray pattern directly onto the fire. Only the heads directly above the fire zone activate — limiting water damage to the fire area only while all other heads remain intact.

Product Range

Available Types & Variants

Pendant (downward discharge)
Upright (upward discharge)
Sidewall (wall-mounted)
Concealed (flush-fit ceiling plate)
Wet Pipe System (standard buildings)
Dry Pipe System (cold storage / freezing areas)

What You Get

Key Features

Fully automatic — no manual action required
Only fire-zone heads activate (no whole-floor flooding)
Wet pipe (standard) and dry pipe (cold storage) types
Standard 68°C activation (special ratings available)
Designed per NBC 2016 and TAC guidelines

Use Cases

Where It's Used

Hotels
Shopping Malls
High-rise Buildings
Hospitals
Warehouses

At a Glance

Technical Specifications

Activation Temp.

68°C standard (57–260°C range)

Coverage Per Head

9–12 m²

Design Pressure

0.5–1.2 bar minimum at head

K-Factor

80 / 115 (standard orifice)

Certification

IS:15105 / LPCB / FM

Keep It Ready

Maintenance & AMC Tips

1

Annual inspection of all heads for corrosion, paint, or physical damage

2

Monthly check of system pressure gauge and alarm valve

3

Never paint or cover sprinkler heads — this voids certification

4

Test flow alarm quarterly by opening the inspector's test valve

5

Replace any head that has activated or shows physical damage immediately

Legal & Compliance Requirement

Sprinklers are mandated by NBC 2016 for buildings over 15m height, hospitals, hotels, and high-occupancy assembly buildings. TAC insurance underwriters require certified sprinkler systems for reduced fire insurance premiums — typically 20–60% savings. Automatic sprinklers have a 96% effectiveness rate in controlling fires to the room of origin before fire brigade arrival.

Get Sprinkler System for Your Premises

Contact our fire safety engineers for a free site visit, product demonstration, and customised quote — no obligation.

ISI/BIS Certified Professional Installation Annual AMC Support Fire NOC Compliance

Keep Exploring

Related Equipment

Zed King Institute of Fire & Safety

ISO 9001:2015 certified leader in Fire Safety Engineering. We provide total peace of mind through BIS approved technologies and Grade-A expertise.

Navigation

  • Home
  • Services
  • About Us
  • Gallery
  • Our Work
  • Blog
  • Contact

Major Services

  • Fire Extinguisher Supply
  • Detection & Alarm Systems
  • Hydrant & Sprinkler Systems
  • Annual Maintenance (AMC)
  • Safety Training
  • NOC & Consultancy

Official Contact

  • Karnal Rd, near New Bus Stand, Friends Colony, Kaithal, Haryana 136027
  • +91-97280 21149
    +91 98123 11612
    +91 94161 11612
  • nareshkumar.ravish@gmail.com

Service Areas Across Haryana

© 2026 Zed-King Fire and Safety. All Rights Reserved.